Send Message
Liandong-U-Gu 17-2#, Shengyuan Road 1#, Jiangkou Street, Fenghua District, Ningbo City, Zhejiang Province, China
Home ProductsPneumatic Manual Valve

Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412

Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412

  • Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412
  • Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412
  • Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412
  • Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412
  • Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412
Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412
Product Details:
Place of Origin: China
Brand Name: Techno
Certification: ISO9001,CE
Model Number: XQ250412
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: carton
Delivery Time: 5 working days
Payment Terms: T/T, Western Union
Supply Ability: 2000 pcs/month
Contact Now
Detailed Product Description
Model: XQ250412 Temperature Characteristics: -10~60 C
Material: Stainless Steel Port Size: G1/8
Operating Pressure: 0~1.0MPa
High Light:

foot pedal valve

,

manual valve actuator

China Factory XQ250412 5/2 1/8" XQ Series Roller Lever High Quality Stainless Steel Mechanical Valve

 

2 Position 3,5 - Port Mechanical Valve

XQ Series

 

Mechanical valves usually use the externa force from cams or rams to change the fluid flowing directions.

When the external forces disappear the valves reset automatically. There are several control types: plunger, roller plunger, roller lever and one way roller lever, 2-Pos. 3-Port and 2-Pos. 5-Port. The P port and R port of a 2-Pos. 3-Port valve can be exchanged so as to change the valve from normally closed to normally open.

When a mechanical valve is installed, the moving direction of the ram should be in α angle against the valve and the plunger should be pressed down a S distance(the direction-changed stroke) as shown in diagram(XQ230410).

 

Specification

 

Model Type Port size Nominal dia.
mm
Operating force Operating
pressure
Fluid
temperature
Ambient
temperature
Service life
XQ230410 3/2 G1/8 4 26N 0~1.0MPa -10~+60℃ 5~60℃ 10
million times
XQ230610 G1/4 6 35N
XQ250410 5/2 G1/8 4 30N
XQ250610 G1/4 6 40N
XQ230411 3/2 G1/8 4 26N
XQ230611 G1/4 6 35N
XQ250411 5/2 G1/8 4 30N
XQ250611 G1/4 6 40N
XQ230412 3/2 G1/8 4 16N
XQ230612 G1/4 6 24N
XQ250412 5/2 G1/8 4 19N
XQ250612 G1/4 6 27N
XQ230413 3/2 G1/8 4 17.8N
XQ230613 G1/4 6 20N
XQ250413 5/2 G1/8 4 21N
XQ250613 G1/4 6 23N

 

 

Pictures detailsStainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412

Stainless Steel Roller Lever Valve 5/2 1/8" Xq Series Mechanical Valve Xq250412

 

 

Delivery
1. If the products we have in store, we will send it out ASAP after payment.
2. If the products which were customized, we will complete the production within a specified period of time, and send it out the first time, we can promise it.
3. We have a variety of ways to deliver goods, usually DHL, Fedex, TNL will be normal ways, If you require use of a courier, we can do it.
4. Also we can send by your delivery acount if you want.

 

Competitive Advantage

Our product features Our Services Guarantee:
1) Competitive price 1) Prompt respond (Reply with 24 hours)
2) Good quality 2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging 3) Registration support.
4) Produce according to Customers’ instruction 4) Photos/videos are available during production.
5) None delay shipment 5) Loading inspection, and send loading photos before shipment.

 

The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.

Contact Details
YIKANG AUTOMATION

Contact Person: Jaren

Tel: 0086-15257858856

Fax: 86-152-57858856

Send your inquiry directly to us (0 / 3000)

Other Products