Send Message
Liandong-U-Gu 17-2#, Shengyuan Road 1#, Jiangkou Street, Fenghua District, Ningbo City, Zhejiang Province, China
Home ProductsDump Truck Controls

HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

  • HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
  • HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
  • HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
Product Details:
Place of Origin: CHINA
Brand Name: Hyva, OEM
Certification: CE,IOS9001
Model Number: 14750650H
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: Negotiation
Packaging Details: Standard Carton,and other special packing according to customer's requirement
Delivery Time: 1-7 work days
Payment Terms: Western Union,T/T,Paypal,credit card
Supply Ability: 2000set/month
Contact Now
Detailed Product Description
Brand: HYVA,OEM Connection: G1/8, M5,M6
Max. Pressure: 12 Bar Min. Pressure: 5 Bar
Max. Temperature: +80° Min. Temperature: -40°
High Light:

automatic control valve

,

pneumatic mechanical valve

HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

 
Description:

part no.                  description                                                  qty

147 50 644 H          control pneumatic - 2 - TF/LF - PN               1

147 50 646 H          control pneumatic - 2 - TS/LF - PN               1

147 50 650 H          control pneumatic - 2 - TF/LF - PA                1

147 50 652 H          control pneumatic - 2 - TS/LF - PA                1

 

Explanation of codes:

❐  2        =    control has 2 sections

❐  TF     =    lever is fixed in tipping end position

❐  TS     =    lever has a spring return in tip position

❐  LF      =    lever is fixed in lowering end position

❐  PNL   =    P.T.O. control has no automatic disengage

P.T.O. control has a lamp

❐  PAL   =    P.T.O. control has an automatic disengage

P.T.O. control has a lamp


Drawings
 
HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

1     : = air inlet
3     : = air exhaust
21  : = lowering connection

(to tipping valve)

22  : = tipping connection

(to tipping valve)

23  : = working port P.T.O.
 
Mounting of the air control:
 
 
When the air control is mounted next to the drivers seat a strong support should be used.
Available supports are:
-   092 32 002 for on-seat mounting
-   092 05 002 for on-floor mounting
Use always rubber grommets to protect air tubes and to prevent that dust and water enters the cabin.
For trouble free life of the entire pneumatic system the air system must be free from water.
The air control should be mounted in such a way that:
1   it is easy to reach by the operator.
2   it is no obstacle when entering or leaving the cabin.
3   it is clear from any moving parts such as drivers seat and closed door.
   The air exhaust connection must be brought outside the
cabin to prevent air entering the cabin, which gives the following disadvantages:
1   noise
2   blown up sand and dust
3   when alcohol is used to prevent the pneumatic system against frost the alcohol vapour will enter the cabin
o Make sure that air tubes:
1   are not too close to sharp objects.
2   are clear from moving parts.
3   are clear from exhaust and compressor lines.
4   can not get kinked.
5   are not too long.
note:     The air supply must always be tapped off from a accessory air tank or auxiliary valve and the 
pneumatic system must be protected with a charging valve.
( see guide - lines from truck manufacturer )
For operation of the air control see the Hyva
operation and maintenance instructions
 
Note: 

The air supply must always be taken from an accessory air tank or auxiliary valveand the pneumatic system must be protected with a charging valve.

HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
 
HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

pos.       part no.           Description                                        qty.

1             147 50 644 H  control pneumatic - 2 - TF/LF - PNL   1

147 50 646 H  control pneumatic - 2 - TS/LF - PNL   1

147 50 650 H  control pneumatic - 2 - TF/LF - PAL   1

147 50 652 H  control pneumatic - 2 - TS/LF - PAL   1

2,3,4,5   147 50 119 K   air kit P.T.O./ valve                             1

2             148 10 517       coupling for air control G1/8”               5

3             148 10 515       coupling for air control M5                   1

4             148 75 500       air tube tie                                               8

5             148 75 007       air tube 6x4 ( 25 m )                                1

6,7,8       147 54 010       charging valve kit            optional       1

7             148 84 501       washer 27x22                    optional       1

8             148 11 005       coupling m 22-6 mm        optional       1

092 32 002       mounting support            optional       1

092 05 002       mounting sup. (angled)   optional        1

HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

 

Competitive Advantage:
 

Our product features: Our Services Guarantee:
1) Competitive price 1) Prompt respond (Reply with 24 hours)
2) Good quality 2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging, 3) Registration support.
4) Produce according to Customers’ instruction 4) Photos/videos are available during production.
5) None delay shipment

5) Loading inspection, and send loading photos before shipment.
 

 
Quality Standards :
 

The company for the products are brand new original products, no second-hand and refurbished products, or leave a compensable ten and return the full amount , but the buyer due to our purchase of model error is not responsible for returns, another of the company's sales of products enjoy one year from the date of shipment quality assurance , according to the original quality standards , during warranty with product problems , need confirmation testing by the manufacturer , the supplier to be solved , the demand side due to storage , use, poor maintenance caused by lower-quality product , and not raise objections 
 
Warranty:
 

All item Comes with Basic 3 Month Sellers Warranty, if item defective in 3 Month, We will offer replacement without extra Charger(including shipping fee)After we Receive the Defective item.
If item Defective after 3 Month, Buyers can still send it back, We will contact suppliers or Manufactory for Warranty. Buyers Might Need to pay the Shipping fee For resend the replaced item.
 

Contact Details
YIKANG AUTOMATION

Contact Person: Jaren

Tel: 0086-15257858856

Fax: 86-152-57858856