NORTHMAN SWM-G02 SERIES FORK LIFT MOBILE TRANSMISSION HYDRAULIC DIRECTIONAL CONTROL VALVE
Basic Properties
Place of Origin:China Taiwan
Brand Name:Northman
Model Number:SWM-G02-C4-D24 SWM-G02-C4-D12
Trading Properties
Minimum Order Quantity:1
Price:35-95USD
Standard Packaging:poly bags, box, cartons, pallets
Delivery Time:3-12working days
Payment Terms:T/T, Western Union, ,Paypal
Supply Ability:500 pcs per week
Specifications
| Mounting Pattern: | ISO 03 /NFPA D03 /CETOP 03 / NG 06 | Maximum Operating Pressure: | 210 Kgf/cm2 (3000 PSI) |
|---|---|---|---|
| Body Material: | Carbon Steel | Insulation: | Class H |
| Surge Protection: | Option Built-in Diode, Surge Voltage < 1 Voltage | Protection Class: | IP65 |
| Temperature Range: | -25° C To +90° C (-13° F To +194° F) | Hydraulic Fluids: | Mineral Oil, Viscosity 10 - 400 CST |
| Waterproof Tolerance: | JIS 0203S2 To Immerse In 30 ℃ (86 ℉) Water@ 100mm (3.94 Inch) In 10 Minutes | Maximum Frequency Of Operation: | 250 Cycles/minute |
| Highlight | Mobile Transmission Hydraulic Directional Control Valve,solenoid operated hydraulic valve |
||
Product Description
ORTHMAN SWM-G02 SERIES FORK LIFT MOBILE TRANSMISSION HYDRAULIC DIRECTIONAL CONTROL VALVE
Codes:
SWM-G02-C4-D24
SWM-G02-C4-D12

Description 4 Way - 3 Position- Spring Centered Mobile Transmission Hydraulic Valve, Float Center
Spool, ISO 03/NFPA D03/NG6 Mtg Pattern, Push-Pull Coil Series, Push Rod Solenoid End.

| PERFORMANCE SPECIFICATIONS | |
| Mounting Pattern | ISO 03 /NFPA D03 /CETOP 03 / NG 06 |
| Maximum Operating Pressure | 210 kgf/cm2 (3000 PSI) |
| Maximum Tank Line Back Pressure | 70kgf/cm2 (1000 PSI ) |
| Current | 2.2A (DC 12V) |
| 1.1A (DC 24V) | |
| Power Consumption | 26.4 Watts |
| Permissible Voltage Change | Duty Cycle |
| -10 % ~ +10% Continuous | |
| +11 % ~ +20% 75% for 5 minutes each energizing | |
| +21% ~ +30% 50% for 3 minutes each energizing | |
| -10 % ~ +10% Continuous | |
| +11 % ~ +20% 75% for 5 minutes each energizing | |
| +21% ~ +30% 50% for 3 minutes each energizing | |
| Insulation | Class H |
| Surge Protection | Option Built-in Diode, Surge Voltage < 1 voltage |
| Permissible Contamination Level | With NAS 1638 Class 12 (ISO 21/18) |
| Operation Fluid and Temperature | Hydraulic Oil: -25 to +90 ℃ (-13 ℉ to + 194℉) |
| Engine Oil: -30℃ to +100℃(-22℉ to +212 ℉ ) | |
| Vibration Tolerance | JIS D1601 Type-3 Class-D Stage-90 @ 0.4mm (0.016 inch) displacement @ 9.0G @ 67 HZ*3 Directions |
| Waterproof Tolerance | JIS 0203S2 To immerse in 30 ℃ (86 ℉) water@ 100mm (3.94 inch) in 10 minutes |
| Maximum Frequency of Operation | 250 cycles/minute |
| Response Time | ≤ 50 msec on ≤ 100 msec off |
| Corrosion Resistance Treatment | Zinc Phosphate Compound |
| Weight | 1.6 kg (3.5 Lbs.) |
Product Tags
Contact Details
Airwolf Automation
Contact Person: Mr. Jaren
Tel: 86-152-5785-8856
Fax: 86-152-57858856