Liandong-U-Gu 17-2#, Shengyuan Road 1#, Jiangkou Street, Fenghua District, Ningbo City, Zhejiang Province, China | airwolf@flyautomatic.com |
Place of Origin: | China |
Brand Name: | Orion |
Certification: | CE |
Model Number: | AD-5 |
Minimum Order Quantity: | 1 piece |
---|---|
Price: | Negotiation |
Packaging Details: | Plastic bags,Boxes, Cartons, Pallets,or according to customer's requirement |
Delivery Time: | within 1-7 working days after payment |
Payment Terms: | Western Union, T/T, L/C, Paypal, Credit card |
Supply Ability: | 1000 pcs |
Suitable For: | Refrigeration Facilities | Operating Pressure: | 0.29~0.98MPa |
---|---|---|---|
Operating Temperature: | 2~60℃ | Inlet: | 1/2“ |
Outlet: | 1/2“ | Original: | CHINA |
Highlight: | auto vehicle parts,car auto parts |
Orion Stainless Steel Auto Drain Valve Refrigeration Facilities Filter AD - 5
Ordering Code: AD-5
Specification
1. Note: The product is for industrial. Please attention to use.
2. For the proper operation of the product, please readthis carefully.
For security, be sure to comply with it.
Warning: if use it in a wrong way, may cause the user serious injury or death.
1. When clean, repair and check, please pumping out the compressed air in the pressure container. If there is residual air, the component will fly up, cause damage.
2. For installation, must according to this manual. Wrong installation will cause water leakage or air leakage.
3. Do not use other liquid, only the specified. Authorized liquid, is compressed air, Others may cause the product broken, like breakdown, leakage and etc.
4. Confirm the piping of drainage. Inappropriate piping, will cause leakage and get wet the facility.
5. When transfer and lend the products, please transmit the manual too. When sell or transfer the used products, in order to let the new user could use safely, please place the manual obviously.
6. No drain without water. Please close the handle of the inlet drainage device. Or, the valve core will be abnormal abrasion.
7. How to keep the product (Long time without use)
1). Dismantle the product after close the ball valve.
2). Drain out the water in drain-pipe. Get rid of the water in the drainage device. Observe from the bottom up, turn right, to drain out the water in the cup.
3). Keep away the garbage, dust and rainwater when keep the product.
Attention: If there's water residual in the drain-pipe, will cause the internal parts corrosion and damage, lead to breakdown.
Installation
1. Attention: As include plastic parts, cannot be installed at the environment which contains the following materials. Direct sunlight also should be avoid.
Chemicals Type | Type | Main products | General use |
Inorganic chemicals | Acid | Hydrochloric acid, Sulfuric acid, Fluorine acid, Phosphoric acid, Chromic acid, etc | Metal pickling solution, Acidic degreaser, Leather coating liquid |
Orgnic chemicals | Aromatic hydrocarbon | Benzene, Toluene, Xylene, Ethylbenzene, Styrene, etc | Paint diluent |
Alcohol | Methyl alcohol, Medicinal alcohol, Cyclohexylethanol, Benzil alcohol, etc | Antifreeze liquid | |
Phenol | Methyl carbonate, Cresol, Naphthol, etc | Raw material of Detergent and Phenol resin | |
Ketone | Acetone, Methyl ethyl ketone, Cyclohexanone, Acetopheneone acid, etc | ||
Carbon acid | Formic acid, Acetic acid, Butyric acid, Acrylic acid, Oxalic acid, Phthalate, etc | Chemical base of Dyeing agent and Aluminum coating treatment | |
Oxygen acid; Alkyd | Glycolic acid, Lactic acid, Malic acid, Citric acid, etc |
Food additive | |
Amine | Methylamine, Dimethylamine, Ethylamine, Aniline, Acetainilide, etc |
Brake oil additives, Antistatic agent, Dye for plastic |
2. Installation method.
Note: When install the drain-pipe, please be sure the status in outlet. Inappropriate piping, will cause leakage and get wet the facklity.
1). Pipe size
Inlet: Rc1/2 Outlet: Rc1/2
2). Installation and piping of drainage
When the drain-pipe outlet is downward, the product should be vertical installation. Check valve must be installed at the drain-pipe inlet.
Application method
1. Regulate the water displacement
The working clearance of drainage device will be different, according to the load and pressure. Cannot regulate the valve when the cup filed with water.
2. Note: Water comes from the compressed air is limited, so please do not set for empty working continuous. If not, will cause:
1). Valve core will be abnormal abrasion.
2). The insterstice will get shorter.
3). Abrasion will be speed up.
4). Spray continuously.
3. Note: If there is too much oil, will cause:
1). Output will be reduced.
2). The interstice will get longer. If there is too much oil, please regulate the oil regulator.
Product show:
Quality Standards :
The company for the products are brand new original products, no second-hand and refurbished products, or leave a compensable ten and return the full amount , but the buyer due to our purchase of model error is not responsible for returns, another of the company's sales of products enjoy one year from the date of shipment quality assurance , according to the original quality standards , during warranty with product problems , need confirmation testing by the manufacturer , the supplier to be solved , the demand side due to storage , use, poor maintenance caused by lower-quality product , and not raise objections
Warranty:
All item Comes with Basic 3 Month Sellers Warranty, if item defective in 3 Month, We will offer replacement without extra Charger(including shipping fee)After we Receive the Defective item.
If item Defective after 3 Month, Buyers can still send it back, We will contact suppliers or Manufactory for Warranty. Buyers Might Need to pay the Shipping fee For resend the replaced item.
Competitive Advantage:
Our product features: | Our Services Guarantee: |
1) Competitive price | 1) Prompt respond (Reply with 24 hours) |
2) Good quality | 2) Free Samples (Customer pay for the delivery cost) |
3) Professional Packaging, | 3) Registration support. |
4) Produce according to Customers’ instruction | 4) Photos/videos are available during production. |
5) None delay shipment |
5) Loading inspection, and send loading photos before shipment.
|
Contact Person: Jaren
Tel: 0086-15257858856
Fax: 86-152-57858856
Quick Clamp PLF Pisco Female Elbow Zinc Brass Metric Pneumatic Tube Fittings
Quick Clamp PD Pisco Branch Tee Zinc Brass Pneumatic Tube Fittings
Quick Connect PB Pisco Tee Zinc Brass Pneumatic Tube Fittings
PCF Pisco Female Straight One Touch Zinc Brass Pneumatic Tube Fittings
DC12V, DC24V RCA3D2 FLY/AIRWOLF Remote Pilot Control Pulse Jet Valves 1/8” With Spade connection
RCA45DD 1-1/2 inch DD Series Australia FLY/AIRWOLF Pneumatic Pulse Jet Valves
CA-50T,RCA-50T IP65 RCA FLY/AIRWOLF Pulse Jet Valves 0.35-0.85Mpa
Diaphragm Valves VNP206 VEM206 200 Series DB16 Diaphragm Repair Kit
Brass Steam Solenoid Valves (US) 2L170-10,2L170-15,2L170-20,2L200-25,2L300-35,40,2L500-50
20mm Orifice Unid 2 Way Brass Water Solenoid Valves Replacement 2W200-20
16mm Orifice Unid 2 Way Brass Water Solenoid Pressure Valves 2W160-15
24V 4.0mm Orifice Unid 2 Way Brass Water Solenoid Valves 2W040-10