Xikou,Fenghua,Zhejiang Province, China
Home ProductsDump Truck Controls

HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

    • HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
    • HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
    • HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
  • HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

    Product Details:

    Place of Origin: CHINA
    Brand Name: Hyva, OEM
    Certification: CE,IOS9001
    Model Number: 14750650H

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 piece
    Price: Negotiation
    Packaging Details: Standard Carton,and other special packing according to customer's requirement
    Delivery Time: 1-7 work days
    Payment Terms: Western Union,T/T,Paypal,credit card
    Supply Ability: 2000set/month
    Contact Now
    Detailed Product Description
    Brand: HYVA,OEM Connection: G1/8, M5,M6
    Max. Pressure: 12 Bar Min. Pressure: 5 Bar
    Max. Temperature: +80° Min. Temperature: -40°

    HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

     
    Description:

    part no.                  description                                                  qty

    147 50 644 H          control pneumatic - 2 - TF/LF - PN               1

    147 50 646 H          control pneumatic - 2 - TS/LF - PN               1

    147 50 650 H          control pneumatic - 2 - TF/LF - PA                1

    147 50 652 H          control pneumatic - 2 - TS/LF - PA                1

     

    Explanation of codes:

    ❐  2        =    control has 2 sections

    ❐  TF     =    lever is fixed in tipping end position

    ❐  TS     =    lever has a spring return in tip position

    ❐  LF      =    lever is fixed in lowering end position

    ❐  PNL   =    P.T.O. control has no automatic disengage

    P.T.O. control has a lamp

    ❐  PAL   =    P.T.O. control has an automatic disengage

    P.T.O. control has a lamp


    Drawings
     
    HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

    1     : = air inlet
    3     : = air exhaust
    21  : = lowering connection

    (to tipping valve)

    22  : = tipping connection

    (to tipping valve)

    23  : = working port P.T.O.
     
    Mounting of the air control:
     
     
    When the air control is mounted next to the drivers seat a strong support should be used.
    Available supports are:
    -   092 32 002 for on-seat mounting
    -   092 05 002 for on-floor mounting
    Use always rubber grommets to protect air tubes and to prevent that dust and water enters the cabin.
    For trouble free life of the entire pneumatic system the air system must be free from water.
    The air control should be mounted in such a way that:
    1   it is easy to reach by the operator.
    2   it is no obstacle when entering or leaving the cabin.
    3   it is clear from any moving parts such as drivers seat and closed door.
       The air exhaust connection must be brought outside the
    cabin to prevent air entering the cabin, which gives the following disadvantages:
    1   noise
    2   blown up sand and dust
    3   when alcohol is used to prevent the pneumatic system against frost the alcohol vapour will enter the cabin
    o Make sure that air tubes:
    1   are not too close to sharp objects.
    2   are clear from moving parts.
    3   are clear from exhaust and compressor lines.
    4   can not get kinked.
    5   are not too long.
    note:     The air supply must always be tapped off from a accessory air tank or auxiliary valve and the 
    pneumatic system must be protected with a charging valve.
    ( see guide - lines from truck manufacturer )
    For operation of the air control see the Hyva
    operation and maintenance instructions
     
    Note: 

    The air supply must always be taken from an accessory air tank or auxiliary valveand the pneumatic system must be protected with a charging valve.

    HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position
     
    HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

    pos.       part no.           Description                                        qty.

    1             147 50 644 H  control pneumatic - 2 - TF/LF - PNL   1

    147 50 646 H  control pneumatic - 2 - TS/LF - PNL   1

    147 50 650 H  control pneumatic - 2 - TF/LF - PAL   1

    147 50 652 H  control pneumatic - 2 - TS/LF - PAL   1

    2,3,4,5   147 50 119 K   air kit P.T.O./ valve                             1

    2             148 10 517       coupling for air control G1/8”               5

    3             148 10 515       coupling for air control M5                   1

    4             148 75 500       air tube tie                                               8

    5             148 75 007       air tube 6x4 ( 25 m )                                1

    6,7,8       147 54 010       charging valve kit            optional       1

    7             148 84 501       washer 27x22                    optional       1

    8             148 11 005       coupling m 22-6 mm        optional       1

    092 32 002       mounting support            optional       1

    092 05 002       mounting sup. (angled)   optional        1

    HYVA 14750650H Led Dump Truck Controls Air Control 2 Sections Fix Tipping Position

     

    Competitive Advantage:
     

    Our product features: Our Services Guarantee:
    1) Competitive price 1) Prompt respond (Reply with 24 hours)
    2) Good quality 2) Free Samples (Customer pay for the delivery cost)
    3) Professional Packaging, 3) Registration support.
    4) Produce according to Customers’ instruction 4) Photos/videos are available during production.
    5) None delay shipment

    5) Loading inspection, and send loading photos before shipment.
     

     
    Quality Standards :
     

    The company for the products are brand new original products, no second-hand and refurbished products, or leave a compensable ten and return the full amount , but the buyer due to our purchase of model error is not responsible for returns, another of the company's sales of products enjoy one year from the date of shipment quality assurance , according to the original quality standards , during warranty with product problems , need confirmation testing by the manufacturer , the supplier to be solved , the demand side due to storage , use, poor maintenance caused by lower-quality product , and not raise objections 
     
    Warranty:
     

    All item Comes with Basic 3 Month Sellers Warranty, if item defective in 3 Month, We will offer replacement without extra Charger(including shipping fee)After we Receive the Defective item.
    If item Defective after 3 Month, Buyers can still send it back, We will contact suppliers or Manufactory for Warranty. Buyers Might Need to pay the Shipping fee For resend the replaced item.
     