Send Message
Liandong-U-Gu 17-2#, Shengyuan Road 1#, Jiangkou Street, Fenghua District, Ningbo City, Zhejiang Province, China
Home ProductsPulse Jet Valves

24VDC SCG353A047 1.5 Inch Pulse Jet Valves

24VDC SCG353A047 1.5 Inch Pulse Jet Valves

  • 24VDC  SCG353A047 1.5 Inch Pulse Jet Valves
  • 24VDC  SCG353A047 1.5 Inch Pulse Jet Valves
  • 24VDC  SCG353A047 1.5 Inch Pulse Jet Valves
  • 24VDC  SCG353A047 1.5 Inch Pulse Jet Valves
  • 24VDC  SCG353A047 1.5 Inch Pulse Jet Valves
  • 24VDC  SCG353A047 1.5 Inch Pulse Jet Valves
24VDC  SCG353A047 1.5 Inch Pulse Jet Valves
Product Details:
Place of Origin: China, USA
Brand Name: or OEM
Certification: ce
Model Number: SCG353A047
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: price negotiable
Packaging Details: Boxes, Cantons, Plastic bags
Delivery Time: within 1-30 working days after payment
Payment Terms: T/T in advance,Western Union,Paypal,Credit card
Supply Ability: 2000 pcs
Contact Now
Detailed Product Description
Body: Aluminium Core Tube: Stainless Steel
Seals & Disc: NBR (nitrile) Differential Pressure: 0,35 - 8,5 Bar [1 Bar = 100kPa]
Ambient Temperature Range: -20 To +85°C
High Light:

1.5 Inch Pulse Jet Valves

,

SCG353A047

,

24VDC Pulse Jet Valves

 

SCG353A047 1.5Inch right angle 24VDC 220VAC 2/2 way valve pulse

 

FEATURES
• The pulse diaphragm valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to produce reliable and economical operation

• The high flow, angle type bodies in combination with the special main diaphragm assemblies give theunique operating features required for dust collector service applications
The design with integral compression fittings will facilitate installation because there is no need for threaded piping
The high quality diaphragms are reinforced and wear resistant to guarantee a long operating life, even under harsh conditions

• Integral pilot operated valves satisfy all relevant EC directives

 

Ordering Code Port Size Orifice Flow Value Coil type
G Threaded mm m3/h l/min
SCG353A047 1 1/2" 52 46 768 400425
SCG353A050 2" 66 77 1290 400425
SCG353A051 2 1/2" 66 92 1540 400425
SCG353.060 3" 75 170 2833 400425
 
Construction
Body Aluminum
Core tube Stainless steel
Core and Plugnut Stainless steel
Core Spring Stainless steel
Sealing & disc CR (chloroprene)
Diaphragm NBR(nitrile/buna-n)
Shading coil Copper
Connector DIN43650A
Voltage DC: 24V, AC: 24V,48V,110V,230V
Working Temperature -20 to +85℃
Protection Class IP65
Coil Insulation Class F
Working Pressure 0.35-0.85Mpa

24VDC  SCG353A047 1.5 Inch Pulse Jet Valves

 

Ordering Code A B C D E F G H J K L Weight
SCG353A047 80 50 30 71 130 136 45 G 3/8" 131 160 178 1.40
SCG353A050 80 50 30 95 168 165 45 G 3/8" 165 210 227 2.90
SCG353A051 80 50 30 95 168 165 45 G 3/8" 165 210 227 2.60
SCG353.060 80 50 30 143 240 192 45 G 1/2" 165 258 275 4.10

 

24VDC  SCG353A047 1.5 Inch Pulse Jet Valves

24VDC  SCG353A047 1.5 Inch Pulse Jet Valves

After-sale Service
We can provide a series of after-sale service, such as product introduction, mounting, debugging, technical support and so on.

 

Warranty
All item Comes with Basic 3 Month Sellers Warranty, if item defective in 3 Month, We will offer replacement without extra Charger(including shipping fee)After we Receive the Defective item.
If item Defective after 3 Month, Buyers can still send it back, We will contact suppliers or Manufactory for Warranty. Buyers Might Need to pay the Shipping fee For resend the replaced item.

 

The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.

 