Product Details:
Place of Origin: China, USA
Brand Name: or OEM
Certification: ce
Model Number: G353A048
Payment & Shipping Terms:
Minimum Order Quantity: 1 piece
Price: price negotiable
Packaging Details: Boxes, Cantons, Plastic bags
Delivery Time: within 1-30 working days after payment
Payment Terms: T/T in advance,Western Union,Paypal,Credit card
Supply Ability: 2000 pcs
Contact Now
Detailed Product Description
Body: Aluminium Springs: Stainless Steel
Diaphragms: CR (chloroprene) Differential Pressure (PS): 0,35 - 8,5 Bar [1 Bar = 100kPa]
Ambient Temperature Range: -20 To +85°C
High Light:

G353A048 Pulse Jet Valves

,

G2" Pulse Jet Valves

,

Dust Collector Bag Pulse Valves

G2 " G353A048 Angle Type Aluminium Pulse Jet Valves For dust collector bag

 

 

CONSTRUCTION
Body Aluminium
Springs Stainless steel
Diaphragms CR (chloroprene)

 

GENERAl
Differential pressure (PS) 0,35 - 8,5 bar [1 bar = 100kPa]
Ambient temperature range -20 to +85°C


G2" G353A048 Pulse Jet Valves For Dust Collector Bag G2" G353A048 Pulse Jet Valves For Dust Collector Bag

 

 

FEATURES
• The pulse valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and
closing to produce reliable and economical operation
• The high flow, angle type bodies in combination with the special main diaphragm assemblies give the unique operating features required for dust
collector service applications
• Integral compression fittings for fast, easy, secure installation
• Valves can be supplied according to ATEX Directive 94/9/EC for non-electrical equipment by using suffix GD
• The components satisfy all relevant EC directives

 

SPECIFICATIONS

pipe size orifice size flow coefficient Kv operating pressure differential (bar) catalogue number OPTION FPM
mln. max. (PS)
air
(mm) (m3/h) (l/min) -/= standard ATEX II2G/D
G - Threaded pipe connection
1 1/2 52 46 768 0,35 8,5 G353A046 G353A046 GD V
2 66 77 1290 0,35 8,5 G353A048 G353A048 GD V
2 1/2 66 92 1540 0,35 8,5 G353A049 G353A049 GD V
3 76 170 2833 1,0 6,0 G353-058 G353-058 GD⑴ V

 
 

G2" G353A048 Pulse Jet Valves For Dust Collector Bag

catalogue number A B C D E F G H weight
G353A046 (GD) 30 G 1/8" 71 130 136 G3/8" 90 120 1,10
G353A048 (GD) 30 G 1/4" 95 168 165 G3/4" 121 166 2,60
G353A049 (GD) 30 G 1/4" 95 168 165 G3/4" 121 166 2,30
G353-058 (GD) 48 G 1/4" 143 240 192 G1/2" 121 214 3,70
G353A063 (GD) 30 G 1/8" 87 177 136 G3/8" 96 183 1,43

 

Competitive Advantage
Our product features Our Services Guarantee:
1) Competitive price 1) Prompt respond (Reply with 24 hours)
2) Good quality 2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging 3) Registration support.
4) Produce according to Customers’ instruction 4) Photos/videos are available during production.
5) None delay shipment 5) Loading inspection, and send loading photos before shipment.

 

The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.

 

 